The SetWiring method sets connection type depending on parameters passed to this method
Parameters:
- Dtr, Rst, Out1, Out2 [in] : line signals may have following values depending on which port you want connect to:
Value | Meaning | Hex |
WIRED_TO_DCD | setting connection to remote DCD line | 0x80 |
WIRED_TO_RI | setting connection to remote RI line | 0x40 |
WIRED_TO_DSR | setting connection to remote DSR line | 0x20 |
WIRED_TO_CTS | setting connection to remote CTS line | 0x10 |
Return Values : If the function succeeds, the return value is TRUE, alternatively, the return value is FALSE.
Note: Method is available for Windows NT4/2000/XP/2003/Vista only.
The default pinout is the following:
Note: DCD signal is connected to DTR signal by default and you are not able to manage them separately. To resolve this problem, please, execute the following command: SetWiring (WIRED_TO_DSR, WIRED_TO_CTS, 0,0). Besides, SetWiring method is actual till virtual port is not deleted from system.